Assay
PGDB_AS002025
System: cell_basedTarget: IKZF2
Assay context summary
Assay context
Activity compounds and values
Activity records
| Structure | Metric | Control | Relation | Value | Unit | Concentration | Time | Target | E3 | Cell line | Patent | Record ID | Compound | Assay | Details |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A007322 | PGDB_C000863 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A007663 | PGDB_C000874 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A007913 | PGDB_C000932 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A007924 | PGDB_C000762 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A007971 | PGDB_C000780 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A008005 | PGDB_C000926 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A008932 | PGDB_C000823 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A009654 | PGDB_C000831 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A009715 | PGDB_C000907 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A010618 | PGDB_C000767 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A010961 | PGDB_C000861 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A012113 | PGDB_C000880 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A012703 | PGDB_C000799 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A013116 | PGDB_C000952 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A013224 | PGDB_C000958 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A013365 | PGDB_C000893 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A013681 | PGDB_C000828 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A013696 | PGDB_C000841 | PGDB_AS002025 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A014208 | PGDB_C000803 | PGDB_AS002025 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF2 | - | - | CN120548310A | PGDB_A014858 | PGDB_C000815 | PGDB_AS002025 | View |