Assay
PGDB_AS000102
System: cell_basedTarget: IKZF3
Assay context summary
Assay context
Activity compounds and values
Activity records
| Structure | Metric | Control | Relation | Value | Unit | Concentration | Time | Target | E3 | Cell line | Patent | Record ID | Compound | Assay | Details |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A007185 | PGDB_C000747 | PGDB_AS000102 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A007793 | PGDB_C000752 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A008740 | PGDB_C000806 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A009596 | PGDB_C000782 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A009799 | PGDB_C000908 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A009829 | PGDB_C000812 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A010364 | PGDB_C000881 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A010525 | PGDB_C000903 | PGDB_AS000102 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A010715 | PGDB_C000883 | PGDB_AS000102 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A010939 | PGDB_C000904 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A010981 | PGDB_C000929 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A011490 | PGDB_C000822 | PGDB_AS000102 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A013596 | PGDB_C000856 | PGDB_AS000102 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A013756 | PGDB_C000784 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A013978 | PGDB_C000937 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A014312 | PGDB_C000749 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A014568 | PGDB_C000927 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A014583 | PGDB_C000799 | PGDB_AS000102 | View | |
| % Degradation | - | >= | 20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A014671 | PGDB_C000889 | PGDB_AS000102 | View | |
| % Degradation | - | = | 0-20 | % | Concentration series: 500 nM, 50 nM | 24 h | IKZF3 | - | - | CN120548310A | PGDB_A014836 | PGDB_C000960 | PGDB_AS000102 | View |